Product Details:
|
Product Name: | Copper Core PVC Insulated Electric Wire | Conductor Type: | Solid Or Stranded |
---|---|---|---|
Core Material: | Copper | Insulation Material: | PVC |
Color: | Any Color Can Be Customized | Voltage: | 450/700V |
High Light: | 300/500V PVC Copper Building Wire,Copper Building Wire H05V-U,H05V-R pvc insulated copper wire |
450/700V Solid Or Stranded Copper Core PVC Insulated Electric Wire 95 MM²
Introduction:
A layer of non-conductive materials, such as resin, plastic, silicone rubber, PVC, etc., are evenly and hermetically wrapped around the wire to form an insulating layer to prevent electrical leakage, short circuit, electric shock and other accidents caused by contact with the outside world. The wire is called insulated electric wire.
Application:
Bare wires are wires without any insulation or protective layer. In addition to being used as a wire for transmitting electrical energy and information, it can also be used to make components and connecting wires for motors and electrical appliances. Copper, aluminum, copper alloy, and aluminum alloy are generally used. In addition, there are various insulated wires suitable for special requirements, such as low-voltage wires for automobiles, high-voltage ignition wires for automobiles, electrical and electrical lead wires, aviation wires, compensation wires, etc.
Specificaiton:
Product name | Insulated Electric Wire |
Certifications | CE/CCC/ISO |
Standard | IEC60502-1 |
Rated Voltage | 300/500v 450/750v |
Conductor material | Copper |
Insulation Material | PVC |
Number of cores | 1C,2C,3C |
Section area | 0.5MM2 - 120MM2 |
Color | customized |
Packing | 100 meters per roll or customized |
Extended information:
During storage, the cable should be packed in a standardized manner, avoid long-term open-air exposure, and both ends should be sealed reliably. Long-term storage in a humid environment is not allowed, and the cable tray should not be stored flat. The height of the tray should be considered and fixed effectively during transportation. Multiple pallets are not allowed to be lifted at the same time when lifting, and pushing down from high places is strictly prohibited.
Special tools should be used for cable laying, such as cable release frame, guide roller, etc., to prevent mechanical damage during laying and keep away from heat sources. When laying cables through pipes, the inner diameter of the pipes should not be less than 1.5 times the outer diameter of the cables. When multiple cables pass through the pipeline, it is prohibited to squeeze the cables. The total area of the cable should not exceed 40% of the total area of the pipe.
Insulated Electric Wire