Product Details:
|
Product Name: | PVC Insulated Cable For Power Distribution Cabinet | Core: | Copper |
---|---|---|---|
Insulation Material: | PVC | Voltage: | 450/750V |
Jacket: | PVC | Application: | Power Distribution Cabinet |
High Light: | BVR PVC Insulated Cable,Multicore PVC Insulated Cable,multi core pvc insulated cable |
Multicore Copper Core PVC Insulated Cable For Power Distribution Cabinet
Parameter:
Product structure: conductor + insulation. The main conductor material is mostly oxygen-free copper, which is composed of multiple strands of copper wire, and the insulation is PVC;
Executive standard: JB8734-2012/GB5023-2008;
Quality standard: 3C certification;
Rated voltage: The wire is immersed in water for 1 hour, and withstands AC 50Hz2500V (450/750V), 2000V (300/500V) voltage test for 5 minutes without breakdown.
Working temperature: The maximum temperature of normal working should not exceed 70℃, the maximum working temperature of BVR-105 is 105℃, and the laying temperature of wires should not be lower than 0℃;
Allowable bending radius: not less than 4D if the outer diameter of the wire (D) is less than 25mm; not less than 6 (D) if the outer diameter (D) of the wire is 25mm and above.
Color: red, yellow, blue, green, black, brown, yellow-green, white, etc., can be customized according to requirements;
Purpose: It is suitable for lines of power, household electrical appliances, instruments and telecommunications equipment with AC rated voltages of 450/750V and below, and is mostly used in various mechanical equipment, with strong flexibility.
Specificaiton:
Product name | PVC Insulated Cable |
Certifications | CE/CCC/ISO |
Standard | IEC60502-1 |
Rated Voltage | 450/750V |
Conductor material | Copper/Aluminum |
Insulation Material | PVC |
Armoured Material | None/Steel Tape/Steel wire |
Jacket Material | PVC |
Number of cores | 1C,2C,3C,4C,5C,3+1C,3+2C,4+1C |
Section area | 1.5MM2 - 400MM2 |
Nominal cross section(mm2)
|
Core structure/wire diameter(mm)
|
Reference weight(kg/km)
|
Average outer diameter upper limit(mm)
|
Conductor resistance at 20℃≤ (Ω/km)
|
1.0
|
~
|
~
|
~
|
~
|
1.5
|
~
|
~
|
~
|
~
|
2.5
|
19/0.41
|
34.7
|
4.2
|
7.41
|
4
|
19/0.52
|
51.4
|
4.8
|
4.61
|
6
|
19/0.64
|
73.6
|
5.6
|
3.08
|
10
|
49/0.52
|
129
|
7.6
|
1.83
|
16
|
49/0.64
|
186
|
8.8
|
1.20
|
25
|
98/0.58
|
306
|
11.0
|
1.15
|
35
|
133/0.58
|
403
|
12.5
|
0.868
|
50
|
133/0.68
|
553
|
14.5
|
0.641
|
70
|
189/0.68
|
764
|
16.5
|
0.443
|