Product Details:
|
Product Name: | High Voltage 8.7/15KV Armoured Power Cable | Conductor: | Aluminum Core |
---|---|---|---|
Insulation Material: | XLPE | Rated Voltage: | 8.7/15KV |
Type: | High Voltage | Jacket: | PVC |
Standard: | IEC60502 | Armor: | Steel Tape |
High Light: | 15KV 3 Core Aluminium Armoured Cable,8.7KV 3 Core Aluminium Armoured Cable,XLPE high voltage armoured cable |
High Voltage 8.7/15KV Aluminum Core XLPE Insulated Armoured Power Cable
Description:
Cable is a conductor covered with insulation, protective layer, shielding layer, etc., used to transmit power, signal current or signal voltage. Compared with low-voltage overhead lines and low-voltage overhead insulated lines, low-voltage cable lines are more expensive and difficult to deploy and maintain, but due to reliable operation, no poles, no area, inconspicuous, and little influence from the outside world . Widely used in low-voltage distribution system.
NAYBY cable is suitable for AC 50Hz power and distribution lines with rated voltage of 0.6/1kV, and can be used for fixed industrial power applications, underground tunnels, etc. The use of steel wire armoring provides excellent mechanical protection and makes it rigid with large radius .
Construction:
VV22/VLV22-0.6/1-kV-single core
1. Conductor: copper or aluminum, Class 1: solid conductor, or Class 2: stranded conductor
2. Insulation: Polyvinyl chloride PVC
3. Inner sheath: PVC
4. Armor: steel tape
5. Sheath: PVC
Specificaiton:
IEC 60228 Conductors
IEC 60502-1 Extruded insulated power cables and accessories thereto for rated voltages from 1kV (Um=1.2kV) to 30kV (Um=36kV) - Part 1: Cables rated at 1kV (Um=1.2kV) and 3 kV (Um=3.6kV)
Product name | Armoured Electrical Cable |
Certifications | CE/CCC/ISO |
Standard | IEC60502-1 |
Rated Voltage | 0.6/1 KV |
Conductor material | Copper/Aluminum |
Insulation Material | XLPE/PVC |
Armoured Material | None/Steel Tape/Steel wire |
Jacket Material | PVC |
Number of cores | 1C,2C,3C,4C,5C,3+1C,3+2C,4+1C |
Section area | 1.5MM2 - 400MM2 |
Extended information:
During storage, the cable should be packed in a standardized manner, avoid long-term open-air exposure, and both ends should be sealed reliably. Long-term storage in a humid environment is not allowed, and the cable tray should not be stored flat. The height of the tray should be considered and fixed effectively during transportation. Multiple pallets are not allowed to be lifted at the same time when lifting, and pushing down from high places is strictly prohibited.
Special tools should be used for cable laying, such as cable release frame, guide roller, etc., to prevent mechanical damage during laying and keep away from heat sources. When laying cables through pipes, the inner diameter of the pipes should not be less than 1.5 times the outer diameter of the cables. When multiple cables pass through the pipeline, it is prohibited to squeeze the cables. The total area of the cable should not exceed 40% of the total area of the pipe.
Armoured Electrical Cable
Contact Person: admin