Product Details:
|
Product Name: | 5 Core Armored Underground Electrical Cable | Insulation Material: | XLPE |
---|---|---|---|
Conductor Material: | CU/Al | Application: | Construction,Underground,Industrial |
Core: | 1, 2, 3, 3+1, 3+2, 4, 4+1, 5 Core | Sheathed: | PVC |
Standard: | IEC60502 | Armored: | SWA |
High Light: | N2XRY Underground Electrical Cable,Armored 5 Core N2XRY,Armored 5 Core N2XRY Underground |
5 Core XLPE Insulated PVC Sheathed N2XRY Armored Underground Electrical Cable
Structure: Conductor, XLPE insulation, filling, PVC inner sheath, steel wire armor, PVC outer sheath
Voltage: 0.6/1kV
Adopt standard: GB/T 12706-2008 rated voltage 1kV (Um=1.2kV) to 35kV (Um=40.5kV) extruded insulated power cable and accessories
Use characteristics:
1) The maximum rated temperature of the cable conductor is 70℃ for PVC insulation, and 90℃ for XLPE or EPR, HEPR insulation;
2) The maximum temperature of the cable conductor during a short circuit (up to 5s) is not more than 160℃ for PVC insulation, and not more than 250℃ for XLPE or EPR, HEPR insulation;
3) The ambient temperature during cable laying is not less than 0℃. If it is laid below 0℃, the cable should be preheated. The cable bending radius is: single-core cable not less than 20 times the outer diameter, and multi-core cable not less than the cable outer diameter. 15 times of
4) When the rated voltage is greater than 6kV, the outer shield should be peeled off by about 100mm and cleaned up to prevent the semi-conductive shielding layer from discharging along the surface of the conductive core and causing breakdown, causing insulation burnout and unnecessary accident;
5) In the process of laying facilities, prevent water and moisture from entering the cable core to prevent rust and discharge, which will affect the service life of the cable.
Specificaiton:
Product name | Underground Electrical Cable |
Certifications | CE/CCC/ISO |
Standard | IEC60502-1 |
Rated Voltage | 0.6/1 KV |
Conductor material | Copper/Aluminum |
Insulation Material | XLPE/PVC |
Armoured Material | None/Steel Tape/Steel wire |
Jacket Material | PVC |
Number of cores | 1C,2C,3C,4C,5C,3+1C,3+2C,4+1C |
Section area | 1.5MM2 - 400MM2 |
Pledge:
1. Pre-sale service
- Introduce the product and its performance and related technical parameters in use, offer consultation, and answer various questions raised by customers during installation and use.
- According to the customer's introduction of the use environment, use conditions, current carrying capacity and other factors, provide customers with reference and consultation.
2. In-sale service
- Sign ordering contracts with customers in time, and provide customers with immediate consultation on the production progress of the products;
- Supervise whether the product is packaged and transported in accordance with user requirements and regulations;
- Timely track whether the product transportation arrives at the customer safely, on time, with quality and quantity;
3. After-sales service
- Deal with customer calls, letters and visits in a serious and timely manner, and quickly solve various problems found by users;
- If users have any technical quality problems, give them a satisfactory answer within one working day.
Underground Electrical Cable
Contact Person: admin
Tel: +8617711323778