Product Details:
|
Product Name: | 4X1.5 Mm² H05VV-F Shielded Multicore Control Cable | Conductor Material: | Copper |
---|---|---|---|
Insulation: | PVC | Voltage: | Low Voltage |
Jacket: | PVC | Uses: | Engineering Electrical Appliances, Etc. |
High Light: | 4X1.5 Mm2 RVV Shielded Cable,4X1.5 Mm2 RVV Shielded,4X1.5 Mm2 Multicore Control Cable |
4X1.5 Mm² Low Voltage H05VV-F RVV Shielded Multicore Control Cable
Introduction:
The full name of RVV cable is copper core PVC insulated PVC sheathed flexible cable, also known as light PVC insulated poly, commonly known as soft sheathed wire, which is a kind of sheathed wire. RVV wire and cable is two or more RV wires plus a layer of sheath. RVV cable is the most commonly used cable for weak current systems. The number of core wires is variable, two or more, and there is a PVC sheath on the outside. There is no special requirement for the arrangement of the core wires. The letter R represents the flexible cord and the letter V represents the insulator polyvinyl chloride (PVC)
For example:RVV2*0.5 means 2 wires of 0.5 square millimeter plus a layer of outer sheath. The function of the sheath is:
1. Protect the inner sheath of the cable from mechanical damage and chemical corrosion;
2. Enhance the mechanical strength of the cable.
The main purpose of RVV cable: used in power lines, control lines and signal transmission lines for electrical appliances, meters, electronic equipment and automation devices, and can be specifically used for anti-theft alarm systems, building intercom systems, etc.
Specificaiton:
Product name | Multicore Control Cable |
Certifications | CE/CCC/ISO |
Standard | IEC60502-1 |
Rated Voltage | 300V/500V |
Conductor material | Copper/Aluminum |
Insulation Material | PVC |
Armoured Material | None/Steel Tape/Steel wire |
Jacket Material | PVC |
Number of cores | 1C,2C,3C,4C,5C,3+1C,3+2C,4+1C |
Section area | 1.5MM2 - 400MM2 |
Number of cores×standard cross section (mm)
|
Specification
|
Insulation thickness specified value (mm)
|
Specified value of sheath thickness (mm)
|
Conductor resistance Ω/km at 20℃ is not more than
|
|
Copper core
|
Galvanized copper core
|
||||
2×0.5
|
16/0.20
|
0.5
|
0.6
|
39.0
|
40.1
|
2X0.75
|
24/0.20
|
0.6
|
0.8
|
26.0
|
26.7
|
2X1
|
32/0.20
|
0.6
|
0.8
|
19.5
|
20.0
|
2X1.5
|
30/0.25
|
0.7
|
0.8
|
13.3
|
13.7
|
2X2.5
|
49/0.25
|
0.8
|
1.0
|
7.98
|
8.21
|
3×0.5
|
16/0.20
|
0.6
|
0.6
|
39.0
|
40.1
|
3X0.75
|
24/0.20
|
0.6
|
0.8
|
26.0
|
26.7
|
3X1
|
32/0.20
|
0.6
|
0.8
|
19.5
|
20.0
|
3X1.5
|
30/0.25
|
0.7
|
0.9
|
13.3
|
13.7
|
3X2.5
|
49/0.25
|
0.8
|
1.1
|
7.98
|
8.21
|
4X0.75
|
24/0.20
|
0.6
|
0.8
|
26.0
|
26.7
|
4X1
|
32/0.20
|
0.6
|
0.9
|
19.5
|
20.0
|
4X1.5
|
30/0.25
|
0.7
|
1.0
|
13.3
|
13.7
|
4X2.5
|
49/0.25
|
0.8
|
1.1
|
7.98
|
8.21
|
5X0.75
|
24/0.20
|
0.6
|
0.9
|
26.0
|
26.7
|
5X1
|
32/0.20
|
0.6
|
0.9
|
19.5
|
20.0
|
5X1.5
|
30/0.25
|
0.7
|
1.1
|
13.3
|
13.7
|
5X2.5
|
49/0.25
|
0.8
|
1.2
|
7.98
|
8.21
|
Multicore Control Cable
Contact Person: admin
Tel: +8617711323778